A flexible studio space, with full production lighting and sound already in place for Your conference, performanceor theatre show. Seating is available for up to 125 in various configurations, from end on to traverse, in the round or with no seating. The possibilities are endless in this versatile space.
Seating capacity
- 98 in Theatre Style
Possible room layouts
- Auditorium/Theatre Style
Stage dimensions
- Stage Width: 12.1m
- Stage Depth: 13.66m (from back wall to front wall)
- 8.2m (with main seating bank extended)
- Wing Space Either Side: 2.6m
- Height to Catwalks: 4m
- Height to Galleries: 3m
- Stage Construction: 18mm ply on solid concrete
Lighting and Electrics
- Power Supply (LX): 4 x 32A supplies down stage right
- 70 x 2.5kW Zero88 chilli dimmer outlets (10A Breakers)
- 8 x 2kW Zero88 chilli independent outlets (10A Breakers)
- 13Amp stage power sockets available throughout venue
- Power Supply (Sound): 13Amp Technical earth circuits onstage & in control booths
- LX Control Location: Above Left Wing in Dedicated Control Room
- LX Control Desk: ETC Congo
- House Light Control: Main entrance, LX control position
- Incoming DMX: From desk and above main seating bank, centre
- Outgoing DMX: Hard line to dimmer switcher
- Power Cables: Adequate stock of 2.5m, 5m and 10m 15Amp TRS cable
Sound
- Sound Control Location: Above Stage Left in Dedicated Control Room
- Mixing Desk: Yamaha LS9 32 channel
- Patch: Full GPO in & out patch
- Mic Inputs: 24 separate mic inputs spread across the venue
- Playback: 2 x Denon Minidisk Decks
- 2 x Denon CD Decks
- Apple Mac G5 with Protools & Qlab. Output on 003 rack
- Amplification: 4 x Crown Microtech 2400
- Speaker Patch: 4-pin XLR multi-speaker patch
- Speakers: 5 x Tannoy V2 Full-range
- 2 x Tannoy T40 Subs
- Microphones: Refer to Academy-wide microphone stock list
- Microphone Cable: Refer to Academy-wide cable stock list
- Intercom: Technical Projects Intercom Hard-wired
- Induction Loop: Yes AVX PDA-1000 Induction Loop System
- Show Relay: Yes Relay hard wired out to source-selectable speakers
- in all parts of the building
Air conditioning
- Yes
Auxiliary electrical supply
- 125amps, 3 phase
Floor plans
- On application
To arrange asite visitand or quotation please contact our Space Planning and External Events Department.
Direct Tel:+ 44 (0) 141 270 8226/8305
Switchboard: + 44 (0) 141 332 4101
Email:venuehires@rcs.ac.uk